Electro Technical

Electo Technical Instruments Calibration Laboratory

Elecrotechnical Calibration Laboratory

At NCQC Laboratory LLP, we provide precise and reliable Electro-Technical Calibration Services to ensure accurate measurement of critical electrical parameters such as voltage, current, resistance, frequency, and power. Our laboratory operates in accordance with ISO/IEC 17025 standards, ensuring full traceability to national and international measurement standards. We also provide Multimeter Calibration Services, Voltmeter Calibration, Oscilloscope Calibration, pH Meter Calibration, Conductivity Meter Calibration, TDS Meter Calibration, and Welding Machine Calibration for industries including pharmaceuticals, engineering, power generation, and manufacturing, where accuracy is essential for safety and quality. Our experienced technical team uses advanced calibration equipment and follows controlled procedures to deliver highly accurate results. We are committed to minimizing measurement uncertainty and maintaining consistency in instrument performance. Our services support regulatory compliance and help organizations improve operational efficiency. With a strong focus on quality and timely service, NCQC Laboratory LLP is a trusted partner for electro-technical calibration.

What is Electro-Technical Calibration?

Electro-Technical Calibration is the process of verifying and adjusting electrical measuring instruments by comparing them with certified reference standards. It ensures that instruments provide accurate and reliable readings within specified limits. This process helps identify measurement errors and ensures proper functioning of equipment. Regular calibration is essential for maintaining safety, product quality, and compliance with international standards. It also reduces measurement uncertainty and enhances the overall performance of instruments. Electro-technical calibration plays a critical role in ensuring consistency and reliability in industrial and laboratory measurements.

Why Industries Across India Trust Our Electro-Technical Calibration Services

Importance of Electro-Technical Calibration

Regular lectro-Technical Calibration helps organizations:

  • Maintain measurement accuracy and reliability
  • Ensure compliance with ISO 9001, ISO 17025, GMP, and regulatory requirements
  • Reduce production errors and product rejections
  • Improve quality assurance and inspection accuracy
  • Maintain traceability to national and international standards
Dimensional Calibration Services
NCQC Calibration Icons

NCQC Calibration Process

Simple Steps, Guaranteed Accuracy

Process steps of instrument calibration

Calibration Process

Our Electro-Technical calibration services follow a systematic process:

1
Visual inspection and cleaning before calibration.
2
Measurement comparison with certified reference standards.
3
Calibration performed in controlled temperature conditions to minimize measurement errors.
4
Instruments are adjusted if necessary and verified for accuracy.
5
Detailed calibration report with traceability to national or international standards.
6
Detailed calibration report with traceability to national or international standards.
7
Detailed calibration report with traceability to national or international standards.

Electro-Technical Calibration is widely used for instruments that measure:

  • Voltage (AC/DC)
  • Current (AC/DC)
  • Resistance
  • Frequency
  • Power and Energy
  • Insulation Resistance
  • Capacitance and Inductance
ParameterRangeMethod for Calibration
1 & 3 Phase Power/ Energy Meter0.15 W - 9600 WDirect calibration with multi function calibrator/ Energy meter calibrator
AC/DC Ammeter (Analog/ Digital)/ Panel Ampere Meter0- 1000 AMultifunction calibrator with current coil
AC/DC Current /0- 1000 AMultifunction calibrator with current coil
AC/DC Voltmeter (Analog/ Digital) / Panel Voltmeters0- 1000 VDirect calibration with multi function calibrator
Capacitance0.50 nf - 110 mFDirect calibration with multi function calibrator
DC Resistance1 Ω- 1090 MΩDirect calibration with multi function calibrator
Decade Capacitance Box1 nF – 10mFDirect Calibration by 6.5 DMM
Decade Resistance Box1 Ω - 1000 MΩDirect Calibration by 6.5 DMM
Digital Multimeter/ Clamp meter: AC/DC Voltage0- 1000 VDirect calibration with multi function calibrator
Frequency / Frequency Meter1 Hz - 2 MHzDirect calibration with multi function calibrator
HV Probe with DMM / kV Meter / HV Tester0-27 kV AC/ 0-40 kV DCComparasion method by HV probe with DMM
Lux Meter25-10050 luxComparison method by light source and lux meter
Multifunction Calibrators4 - 20 mA / 1 - 200 mV /by using multifunction calibrator
Oscilloscope (Amplitude, Bandwidth and time Base)up to 1100 MHzby using multifunction calibrator
pH Meter1- 14 pH"Using Multi–Productcalibrator /Temperature Electrical Calibrator by Simulation Method"
Phase Meter0- 360°Direct calibration with multi function calibrator
Power Factor Meter0-1 pFDirect calibration with multi function calibrator
Power Supply0- 1000V/ 10ADirect Calibration by 6.5 DMM
Resistance decade box1 Ω to 999 MΩDirect Calibration by 6.5 DMM
Shunt0- 20 ADirect calibration with multi function calibrator
Sound Level Meter94 dB, 114 dBDirect calibration by sound level meter
Stop Watch/ Timer / Hour Meter0.01 sec.- 24 hrComparison by Timer and stop watch calibrator
Temperature Simulation (RTD/ Thermocouple) / Temperature controller / Temperature indicator / PID controller-200°C to 1760°CDirect calibration with multi function calibrator
Universal Calibrators / Loop Calibrator / RTD Calibrator / RTD Simulator4 - 20 mA / 1 - 200 mV / Temperature Simulation / Resistance /Direct calibration with multi function calibrator & 6.5 DMM
LCR Meter1Ω - 2 kΩ / 10 µH to 1000 mH / 0.5 nF to 330 µFDirect calibration with multi function calibrator & Inductance Box
Conductivity Meter1 μs to 1000 ms (1 ohm to 1 Mohm)Using Multiproduct calibrator by Simulation Method
Resistance / Resistance Meter / Megger / Insulation tester / Earth tester / Low Resistance Meter / Micro Ohm meter10 µΩ to 1000 GΩUsing Multi-Product Calibrator / Resistance decade box / High resistance Jig by Direct Method
Inductance Meter10 µH to 1000 mHDirect calibration with Inductance Box